[Sampling] Mode=1 MultiConverter=No Interval=1 TimeUnits=5 MaxSamples=990000 ReadingsPerSample=2147483647 EndAction=0 [General] NoOfConverters=1 NoOfParameters=7 NoOfCalc=0 [Converter 1] Port=4 Type=16 [Unit 1 Channel 1] ParamNo=7 Enabled=Yes Resolution=14 Differential=No FilterEnable=No FilterFactor=10 [Unit 1 Channel 2] ParamNo=6 Enabled=Yes Resolution=13 Differential=No FilterEnable=No FilterFactor=10 [Unit 1 Channel 3] ParamNo=5 Enabled=Yes Resolution=13 Differential=No FilterEnable=No FilterFactor=10 [Unit 1 Channel 4] ParamNo=4 Enabled=Yes Resolution=13 Differential=No FilterEnable=No FilterFactor=10 [Unit 1 Channel 5] ParamNo=3 Enabled=Yes Resolution=13 Differential=No FilterEnable=No FilterFactor=10 [Unit 1 Channel 6] ParamNo=2 Enabled=Yes Resolution=16 Differential=No FilterEnable=No FilterFactor=10 [Unit 1 Channel 7] ParamNo=1 Enabled=Yes Resolution=13 Differential=No FilterEnable=No FilterFactor=10 [Parameter 1] Enabled=Yes Monitored=Yes Name=Water Alarms AlarmEnable=Yes AlarmLower=1000.000000 AlarmUpper=2500.000000 AlarmHoldoff=0 InputUnits=mV InputWidth=8 InputPlaces=2 InputMinValue=-2500.000000 InputMaxValue=2500.000000 Conditioner=0 Sensor=0 ConditionerUnits=mV ConditionerWidth=8 ConditionerPlaces=2 ConditionerMinValue=-2500.000000 ConditionerMaxValue=2500.000000 ScaleMethod=0 ScaleText= ScaledUnits=mV ScaledWidth=8 ScaledPlaces=2 ScaledMinValue=-2500.000000 ScaledMaxValue=2500.000000 UserFormatted=Yes UserUnits=mV UserWidth=8 UserPlaces=0 UserMinValue=0.000000 UserMaxValue=2500.000000 [Parameter 2] Enabled=Yes Monitored=Yes Name=Heading AlarmEnable=No AlarmLower=-2500.000000 AlarmUpper=2500.000000 AlarmHoldoff=0 InputUnits=mV InputWidth=8 InputPlaces=2 InputMinValue=-2500.000000 InputMaxValue=2500.000000 Conditioner=0 Sensor=0 ConditionerUnits=mV ConditionerWidth=8 ConditionerPlaces=2 ConditionerMinValue=-2500.000000 ConditionerMaxValue=2500.000000 ScaleMethod=2 ScaleText=(X-83)*359/1720 ScaledUnits=Degrees ScaledWidth=8 ScaledPlaces=0 ScaledMinValue=0.000000 ScaledMaxValue=359.000000 UserFormatted=Yes UserUnits=Degrees UserWidth=8 UserPlaces=0 UserMinValue=0.000000 UserMaxValue=359.000000 [Parameter 3] Enabled=Yes Monitored=Yes Name=Pod Vacuum AlarmEnable=Yes AlarmLower=0.700000 AlarmUpper=0.900000 AlarmHoldoff=0 InputUnits=mV InputWidth=8 InputPlaces=2 InputMinValue=-2500.000000 InputMaxValue=2500.000000 Conditioner=0 Sensor=0 ConditionerUnits=mV ConditionerWidth=8 ConditionerPlaces=2 ConditionerMinValue=-2500.000000 ConditionerMaxValue=2500.000000 ScaleMethod=2 ScaleText=(X+438)/2625 ScaledUnits=Bar ScaledWidth=8 ScaledPlaces=2 ScaledMinValue=0.000000 ScaledMaxValue=2.000000 UserFormatted=Yes UserUnits=Bar UserWidth=8 UserPlaces=2 UserMinValue=0.000000 UserMaxValue=2.000000 [Parameter 4] Enabled=Yes Monitored=Yes Name=Pod Vacuum AlarmEnable=No AlarmLower=0.700000 AlarmUpper=0.900000 AlarmHoldoff=0 InputUnits=mV InputWidth=8 InputPlaces=2 InputMinValue=-2500.000000 InputMaxValue=2500.000000 Conditioner=0 Sensor=0 ConditionerUnits=mV ConditionerWidth=8 ConditionerPlaces=2 ConditionerMinValue=-2500.000000 ConditionerMaxValue=2500.000000 ScaleMethod=2 ScaleText=(X+438)/2625 ScaledUnits=Bar ScaledWidth=8 ScaledPlaces=2 ScaledMinValue=0.000000 ScaledMaxValue=2.000000 UserFormatted=Yes UserUnits=Bar UserWidth=8 UserPlaces=2 UserMinValue=0.000000 UserMaxValue=2.000000 [Parameter 5] Enabled=Yes Monitored=Yes Name=Pod Vacuum AlarmEnable=Yes AlarmLower=0.700000 AlarmUpper=0.900000 AlarmHoldoff=0 InputUnits=mV InputWidth=8 InputPlaces=2 InputMinValue=-2500.000000 InputMaxValue=2500.000000 Conditioner=0 Sensor=0 ConditionerUnits=mV ConditionerWidth=8 ConditionerPlaces=2 ConditionerMinValue=-2500.000000 ConditionerMaxValue=2500.000000 ScaleMethod=2 ScaleText=(X+438)/2625 ScaledUnits=Bar ScaledWidth=8 ScaledPlaces=2 ScaledMinValue=0.000000 ScaledMaxValue=2.000000 UserFormatted=Yes UserUnits=Bar UserWidth=8 UserPlaces=2 UserMinValue=0.000000 UserMaxValue=2.000000 [Parameter 6] Enabled=Yes Monitored=Yes Name=24v Monitor AlarmEnable=Yes AlarmLower=22.000000 AlarmUpper=26.000000 AlarmHoldoff=0 InputUnits=mV InputWidth=8 InputPlaces=2 InputMinValue=-2500.000000 InputMaxValue=2500.000000 Conditioner=0 Sensor=0 ConditionerUnits=mV ConditionerWidth=8 ConditionerPlaces=2 ConditionerMinValue=-2500.000000 ConditionerMaxValue=2500.000000 ScaleMethod=2 ScaleText=X*24.13/2195 ScaledUnits=Volts ScaledWidth=8 ScaledPlaces=2 ScaledMinValue=22.000000 ScaledMaxValue=26.000000 UserFormatted=Yes UserUnits=Volts UserWidth=8 UserPlaces=2 UserMinValue=22.000000 UserMaxValue=26.000000 [Parameter 7] Enabled=Yes Monitored=Yes Name=Depth AlarmEnable=Yes AlarmLower=-2500.000000 AlarmUpper=210.000000 AlarmHoldoff=0 InputUnits=mV InputWidth=8 InputPlaces=2 InputMinValue=-2500.000000 InputMaxValue=2500.000000 Conditioner=0 Sensor=0 ConditionerUnits=mV ConditionerWidth=8 ConditionerPlaces=2 ConditionerMinValue=-2500.000000 ConditionerMaxValue=2500.000000 ScaleMethod=2 ScaleText=(X-4)/10 ScaledUnits=Metres ScaledWidth=8 ScaledPlaces=1 ScaledMinValue=0.000000 ScaledMaxValue=250.000000 UserFormatted=Yes UserUnits=Metres UserWidth=8 UserPlaces=1 UserMinValue=0.000000 UserMaxValue=250.000000 [Monitor] Placement=0,1,-1,-1,-1,-1,0,260,80,208 [Recorder] Placement=0,1,-1,-1,-1,-1,0,260,0,80 [Graph1] Active=No [XYGraph1] Active=No [Spread1] Active=No [File] Filename=